Apartment buildings & common areas

Stairwells, boiler room and parking — the usual file a building manager needs.

What we install & maintain

The systems for this type of space

In an apartment building, fire protection of the common areas is usually the building manager's job. The basics are simple: extinguishers on every floor maintained every year, emergency lighting and, where needed, detection. We maintain, refill and rent extinguishers within Attica.

Regulatory framework

What governs this type of space

Occupancy categoryResidential (P.D. 41/2018, Ch. B, art. 1).
Fire extinguishersOne portable on every floor in the common areas, covering up to 400 m² — otherwise more are added; one in every detached house (1.7.1).
Manual fire alarmIn apartment buildings with three or more floors of main use, with call points near the stairs (1.7.2).
Fire detectionAn automatic system; in buildings of up to three floors of main use, standalone fire detectors (to the manufacturer's specifications) covering at least every bedroom and the kitchen are acceptable instead (1.7.3).
Fire hydrant systemIn apartment buildings over 28 m high with a floor area over 500 m² (1.7.4).
Emergency lightingOn common-area escape routes and at exits (1.4).
Existing buildingsPermit applied for before 17-2-1989: there is no legal framework; Circular 31415/2019 gives only recommended measures, with no obligation or penalties. From 17-2-1989, P.D. 71/1988 — or, for newer buildings, P.D. 41/2018 — is mandatory.

Which framework binds a given building depends on the date the building permit was applied for and on its occupancy classification. The binding requirement comes from the approved fire-safety study.

Frequently asked questions

Apartment buildings & common areas — what clients ask us

Are extinguishers mandatory in an older apartment building?

It depends on when the building permit was applied for. Before 17-2-1989, Circular 31415/2019 gives only recommended, non-mandatory measures. Buildings under P.D. 71/1988 (from 17-2-1989 until P.D. 41/2018) need at least two portable extinguishers in plant rooms with a fire risk; in buildings with 5 or more floors, or with a floor over 500 m², extinguishers are also required in boiler rooms, fuel stores and machine rooms. New buildings (P.D. 41/2018) need one per floor in the common areas. Where they exist, they must be maintained every year.

How often are extinguishers maintained?

Once a year by a Recognised Maintenance Company, with further maintenance and workshop testing in set years (JMD 618/43/2005 as amended). The JMD also recommends routine visual checks by the owner or building manager (location, visibility, legible instructions, damage), at intervals of no more than three months.

Can I rent extinguishers?

Yes — for an annual fee that includes maintenance and replacement, within Attica.